Qosina Bioprocess Catalog 2023

CLAMPS & CLIPS

CLAMPS & CLIPS Securing Clamps Oetiker ® Ear Clamps

Securing Clamps Oetiker ® Ear Clamps

• 2-ear version: extended clamping range

• Fast and simple assembly

• Compact one-piece clamp: for robust, secure connections

• Visible deformation provides evidence of proper closure

• Clamp ear: fast and simple installation, visible deformation provides evidence of proper closure

• Pre-shaped insert for effective and powerful all-around seal

• Deburred edges: reduced risk of damage to parts being clamped

15400012 Oetiker ® Ear Clamp With Insert, Non-Washed 0.114 inch Closed - 0.146 inch Open Range (2.9 mm - 3.7 mm) SS

Works with tools on page 149

15100016 Oetiker ® 2-Ear Clamp, Non-Washed 1.035 inch Closed - 1.22 inch Open Range (26.29 mm - 31 mm) SS

Works with tools on page 149

Also Available: Part No.

Measurement Process Option 15400064 0.165 inch Closed - 0.204 inch Open Range (4.19 mm - 5.18 mm) Non-Washed 15400014 0.185 inch Closed - 0.224 inch Open Range (4.7 mm - 5.69 mm) Non-Washed 15400069 0.185 inch Closed - 0.224 inch Open Range (4.7 mm - 5.69 mm) Degreased 15400023 0.315 inch Closed - 0.374 inch Open Range (8 mm - 9.5 mm) Non-Washed 15400075 0.315 inch Closed - 0.374 inch Open Range (8 mm - 9.5 mm) Degreased 15400089 0.437 inch Closed - 0.515 inch Open Range (11.1 mm - 13.08 mm) Degreased 15400032 0.437 inch Closed - 0.515 inch Open Range (11.1 mm - 13.08 mm) Non-Washed 15400035 0.484 inch Closed - 0.563 inch Open Range (12.29 mm - 14.3 mm) Non-Washed 15400091 0.484 inch Closed - 0.563 inch Open Range (12.29 mm - 14.3 mm) Degreased 15400101 0.504 inch Closed - 0.583 inch Open Range (12.8 mm - 14.81 mm) Degreased 15400036 0.504 inch Closed - 0.583 inch Open Range (12.8 mm - 14.81 mm) Non-Washed

Also Available: Part No.

Measurement

Process Option Non-Washed Non-Washed

15100019 1.26 inch Closed - 1.457 inch Open Range (32 mm - 37 mm) 15100020 1.378 inch Closed - 1.575 inch Open Range (35 mm - 40.01 mm)

• Clamp ear: fast and simple installation, visible deformation provides evidence of proper closure

• Dimple: increases clamping force

• Specially formed strip edges: reduced risk of damage to parts being clamped

Works with tools on page 149

15500023 Oetiker ® 1-Ear Clamp with Mechanical Interlock, Non-Washed 1.358 inch Closed - 1.48 inch Open Range (34.49 mm - 37.59 mm) SS

Works with tools on page 149

15300002 Oetiker ® 1-Ear Clamp, Non-Washed 0.130 inch Closed - 0.161 inch Open Range (3.3 mm - 4.09 mm) SS

Also Available: Part No.

Measurement

Process Option Non-Washed Non-Washed Non-Washed

15500024 1.378 inch Closed - 1.5 inch Open Range (35 mm - 38.1 mm) 15500025 1.437 inch Closed - 1.559 inch Open Range (36.5 mm - 39.6 mm) 15500026 1.492 inch Closed - 1.614 inch Open Range (37.9 mm - 41 mm)

100

101

Customer Service +1 (631) 242 - 3000

Dimensions are for reference only

qosina.com/bioprocess

Customer Service +1 (631) 242 - 3000

Dimensions are for reference only

qosina.com/bioprocess

Powered by