Qosina Bioprocess Catalog 2023

ADHESIVES

ADHESIVES

Solution Guide CYANOACRYLATES FOR DEVICE ASSEMBLY

Solution Guide UV-CURABLE ADHESIVES FOR DEVICE ASSEMBLY

START

What type of material are you bonding?

START

What type of material are you bonding?

Elastomers

Plastic

Glass

Plastic

Metal

Thermosets

Thermoplastic Elastomers & Thermoplastics (e.g., PP, PE, Nylon, PS, HDPE, LDPE, TPU, PET/PETG)

Active Metals (e.g., Brass, Bronze, Copper, Steel)

Inactive Metals (e.g., Nitinol, Aluminum, Nickel, Stainless Steel, Titanium, Anodized Surfaces)

Thermoplastics

Thermosets

(e.g., PC, ABS, PMMA, PVC, Fiberglass, Phenolic)

(e.g., PP, PE, Nylon, PS, HDPE, LDPE, TPU, PET/PETG)

(e.g., PC, ABS, PMMA, PVC, Fiberglass, Phenolic)

Use with 6070 Primer for Increased Adhesion

Medium Viscosity

Medium to High Viscosity

Use with 6070 Primer for Increased Adhesion

Medium to High Viscosity

SOLUTION

6070

M2611

M2028

M2075

1

105

3

750

Viscosity (cPs) Shear Strength (psi) Temperature Range Fixture Time (seconds)

4035*

2700**

3320*

SOLUTION

6070

U304

U305

U307

-67°F to 203°F

-67°F to 203°F

-67°F to 203°F

1

1000 3000*

850

2000 700**

Viscosity (cPs) Shear Strength (psi) Temperature Range Fixture Time (seconds)

10

2

10

3000

-65°F to 200°F

-65°F to 200°F

-65°F to 200°F

175

400

275

SPECIALTY APPLICATION ADHESIVES

* Performance of cured adhesive on Polycarbonate **Performance of cured adhesive on Stainless Steel *** Performance of cured adhesive on Glass

Rubber-Toughened Cyanoacrylates

Low Odor, Low Bloom

Engineered for applications requiring vibration, shock, impact and/or heat resistance, as well as increased flexibility

For applications with aesthetic or fume requirements

Adhesives are not intended for use in the assembly of implantable devices

Low to Medium Viscosity

Low to Medium Viscosity

Low Viscosity

High Viscosity

SOLUTION

M2240-05

M5005

M5008

M5100

500

5

50

1000

Viscosity (cPs) Shear Strength (psi) Temperature Range Fixture Time (seconds)

2600***

2700***

2600***

5200*** -67°F to 266°F 25

For our full list of adhesive references, visit: qosina.com/medical-grade-adhesives

-67°F to 203°F

-67°F to 203°F

-67°F to 203°F

15

20

60

* Performance of cured adhesive on Polycarbonate, tested to ASTM 4501 ** Performance of cured adhesive on PETG, tested to ASTM 4501 ***Performance of cured adhesive on Stainless Steel Fixture time given is for the recommended substrate field (i.e., time for plastic recommendations are for plastic, metal are metal, and all specialty adhesives are shown for fixture time on metal.)

Adhesives are not intended for use in the assembly of implantable devices

158

159

Customer Service +1 (631) 242 - 3000

Dimensions are for reference only

qosina.com • info@qosina.com

Customer Service +1 (631) 242 - 3000

Dimensions are for reference only

qosina.com • info@qosina.com

Powered by